Evaluation and Improvement of Insulation Resistance in Induction Motor Stators Using Corrective Maintenance Methods
Downloads
The reliability of induction motors is strongly influenced by the condition of stator insulation, which commonly deteriorates due to thermal stress, humidity, contamination, and aging. Severe degradation of insulation can cause unexpected breakdowns, power losses, and reduced equipment lifetime. This study aims to evaluate and restore the insulation resistance of a three-phase induction motor through systematic measurement and corrective maintenance.The research was conducted in several stages, beginning with the measurement of insulation resistance using a megohmmeter. The initial results showed values of 0 MΩ for both phase-to-phase and phase-to-ground across all sessions, indicating that the insulation system had completely failed. These values were then corrected to a reference temperature of 40 °C in accordance with IEEE Std 43-2013 to allow accurate comparison. The causes of degradation were identified as contamination, moisture ingress, high operating temperature, vibration, and natural aging of insulation materials. Corrective maintenance actions were applied, including cleaning, drying, varnish impregnation, reinforcement, and complete rewinding. After maintenance, the corrected insulation resistance values improved significantly, reaching up to 2000 MΩ in all sessions, far exceeding the IEEE threshold of 100 MΩ. This improvement demonstrates that the applied methods successfully restored the dielectric integrity of the stator insulation. In conclusion, systematic testing combined with corrective maintenance ensures the recovery of insulation performance, supports reliable motor operation, and extends service life.
L. Szamel, et al., “Monitoring of Stator Winding Insulation Degradation in Electric Motors Using FDS,” Machines, vol. 12, no. 4, p. 220, Apr. 2024. [Online]. Available: https://www.mdpi.com/2075-1702/12/4/220
T. García-Calva, et al., “Early Detection of Faults in Induction Motors—A Review,” Energies, vol. 15, no. 21, p. 7855, Nov. 2022. [Online]. Available: https://www.mdpi.com/1996-1073/15/21/7855
A. Almounajjed, et al., “Diagnosis of stator fault severity in induction motor using high-resolution spectral kurtosis,” Measurement, vol. 186, p. 110168, Dec. 2021. [Online]. Available: https://www.sciencedirect.com/science/article/abs/pii/S026322412100734X
T. A. Kawady, et al., “AI-driven fault diagnosis for stator inter-turn faults in induction machines,” Scientific Reports, vol. 15, no. 1, p. 2398, Feb. 2025. [Online]. Available: https://www.nature.com/articles/s41598-025-04462-x
Y. Ji, et al., “Investigation on combined effect of humidity–temperature on PD in inter-turn insulation,” IET Science, Measurement & Technology, vol. 17, no. 6, pp. 452–462, 2023.[Online].Available:https://ietresearch.onlinelibrary.wiley.com/doi/full/10.1049/smt2.12128
Y. Tu, et al., “Frequency-Domain Dielectric Response of Insulating Paper with High Humidity,” IEEJ Trans. Electr. Electron. Eng., vol. 19, no. 5, pp. 1234–1245, 2024. [Online].Available:
https://onlinelibrary.wiley.com/doi/abs/10.1002/tee.23934
L. Xu, et al., “Dielectric response characteristics and moisture exposure of insulating pressboard,” Measurement, vol. 228, p. 115143, Oct. 2024. [Online].Available:
https://www.sciencedirect.com/science/article/abs/pii/S0263224124006559
B. Sirizzotti, et al., “A Review of Stator Insulation State-of-Health Monitoring Methods,” Energies, vol. 18, no. 14, p. 3758, Jul. 2025. [Online]. Available: https://www.mdpi.com/1996-1073/18/14/3758
Cheng, et al., “A Study of Frequency Domain Reflectometry Technique for Winding Insulation Diagnosis,” Machines, vol. 11, no. 9, p. 883, Sep. 2023. [Online]. Available: https://www.mdpi.com/2075-1702/11/9/883
H. Yoon, et al., “Maintenance of Arc Occurrence at the End of the Stator Slot in High-Voltage Motors,” Machines, vol. 13, no. 4, p. 279, Apr. 2025. [Online]. Available: https://www.mdpi.com/2075-1702/13/4/279
B. Sirizzotti, D. Addae, E. Agamloh, A. Von Jouanne, and A. Yokochi, “A Review of Stator Insulation State-of-Health Monitoring Methods,” Energies, vol. 18, no. 14, p. 3758, Jul. 2025, doi: 10.3390/en18143758.
X. Zhou, et al., “Insulation for Rotating Low-Voltage Electrical Machines,” Energies, vol. 17, no. 9, p. 1987, Apr. 2024. [Online]. Available: https://www.mdpi.com/1996-1073/17/9/1987
IEEE Std 43-2013, “IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery,” IEEE Standards Association, Dec. 2013. [Online]. Available: https://standards.ieee.org/standard/43-2013.html
N. R. Watson, et al., “Insulation aging and diagnostic testing of electric machine stators: A review,” Electric Power Systems Research, vol. 212, p. 108566, Jan. 2023. [Online]. Available:https://www.sciencedirect.com/science/article/pii/S0378779622004682
Faiz, et al., “Review on Stator Insulation Degradation and Fault Diagnosis in Induction Motors,” IEEE Transactions on Dielectrics and Electrical Insulation, vol. 29, no. 6, pp. 2253–2268, Dec. 2022. [Online]. Available: https://ieeexplore.ieee.org/document/9910982
A. B. Pradhan, et al., “Effectiveness of Insulation Maintenance in Induction Motors: A Case Study,” Energies, vol. 16, no. 3, p. 1123, Feb. 2023. [Online]. Available: https://www.mdpi.com/1996-1073/16/3/1123
M. F. Cabanas, et al., “Condition Monitoring of Electrical Machines: State of the Art and Trends,” Machines, vol. 11, no. 6, p. 640, Jun. 2023. [Online]. Available: https://www.mdpi.com/2075-1702/11/6/640
N. Z. Zulkifli, B. Ramadevi, K. Bingi, R. Ibrahim, and M. Omar, “Predicting Remaining Useful Life of Induction Motor Bearings from Motor Current Signatures Using Machine Learning,” Machines, vol. 13, no. 5, p. 400, May 2025, doi: 10.3390/machines13050400.
W. Doorsamy, “Condition Monitoring of Electric Machines: Modern Frameworks and Data-Driven Methodologies,” Machines, vol. 13, no. 2, p. 144, Feb. 2025, doi: 10.3390/machines13020144.
J.-Y. Koo, J.-H. Kwak, H.-D. Kim, and S.-Y. Kim, “Analysis of the Insulation Condition Due to Contamination on the Surface of End-Windings in Large-Capacity High-Voltage Motor,” J. Electrical Engineering and Technology, Mar. 2025. [Online]. Available: https://link.springer.com/article/10.1007/s42835-025-02209-2
Z. Zou, H. Yu, Y. Guo, et al., “Degradation Mechanism and Online Electrical Monitoring of Insulation in Traction Motors,” Energies, vol. 15, no. 10, p. 444, 2024. [Online]. Available: https://www.mdpi.com/2032-6653/15/10/444
A. O. Vitor, “Induction Motor Short-Circuit Diagnosis and Interpretation,” Expert Systems with Applications, vol. 206, p. 117750, 2023. [Online]. Available: https://www.sciencedirect.com/science/article/abs/pii/S0957417423005006
M. Ma, L. Chen, H. Yang, et al., “Residual Stress Analysis at the Conductor–Insulator Interface in Impregnated Coils,” Polymers, vol. 16, no. 24, p. 3514, 2024. [Online]. Available: https://www.mdpi.com/2073-4360/16/24/3514
U. Rösel, M. Kneidl, J. Franke, and D. Drummer, “Improving the Integrated Fabrication of Insulation Systems in Electric Drives by Injection Molding of Thermosets Due to Processing Conditions and Slot Design,” Polymers, vol. 15, no. 5, Art. 1165, 2023. [Online]. Available: https://www.mdpi.com/2073-4360/15/5/1165
G. Zhu et al., “Identification of Dielectric Response Parameters of Pumped Storage Generator–Motor Stator Winding Insulation Based on Sparsity-Enhanced Dynamic Decomposition of Depolarization Current,” Energies, vol. 18, no. 13, Art. 3382, 2025. [Online]. Available: https://www.mdpi.com/1996-1073/18/13/3382